The device performs low-multiple tissue thermal acids under the Low-Ridden Occurate and Defective Acid Test Act for GB226-2015 steel

(b) Corrosion to examine defects in steel raw materials or to make flow lines;

The use of computers and controlled silicon to control thermal acid erosion of low-multiple tissues, and the unique PID temperature control calculation method, eliminate uncertainty in the low-multiple tissue sample process and increase the repetition of low-multiple tissue samples.

Touch screen manipulation shows, simple visual.

The control unit and acid corrosive cell work are designed separately to increase the working life of the control unit.

The acid corrosive cells are made of special materials, are resistant to high temperatures and closed corrosive cells ensure the volatilization of the corrosive solution to environmental pollution and human harm.

The three-layer approach to the segregation of samples has facilitated their removal and increased work space, improving the overall corrosivity.

There are discharge valves that facilitate the discharge of corrosive waste.

Sample trays can be removed completely and clean easily.

Tight acid corrosive tanks, which are fully usable in conjunction with windboxes, increase the comfort of the working environment.

The size diversity is fully customized to meet client requirements.

Product Advantages
✪Corrosion tanks can be customized, power can be increased, and ventilation cabinets, middle and systems can be installed.

✪(a) The use of effective energy-saving devices (integrated modules) to control the acid thermal erosion process in low tissues, which removes uncertainty about the process in low tissue samples and improves detection effectiveness;

✪The electro-heating (module) of the device is strictly controlled and the volatilization of the acid fog can be reduced to a minimum, which can significantly improve the working environment;

✪(a) The power and control components are separated from acid thermal corrosive cells to ensure the corrosivity of the system as a whole, with extended life;

✪This equipment is suitable for use in laboratories with smaller and smaller samples.

Technical Specifications

Temperature range

Room temperature - 100°C

Temperature Control Precision

Error ± 1°C

Temperature Time

0-99min

Clindling function

Control the temperature and timing beeper intermittent alarm

Electronic metrware

Touch screens, single-screen machines

Power voltage

AC-220V 50/60HZ

Heating power

3Kw (other power, voltage custom)

Working temperature

5-40℃

Humidity

0-95% relative humidity

Effective Dimensions

400 mm long 400 mm long

Outer Size

520 mm long 496 mm long 550 mm high

Weight

20Kg


Download

Download Materials:

Order

Thank you for your attention to Fuyun products and solutions! Please fill out the following form to make us aware of your needs.

Marked*- You're not gonna get it.

  • Product Type*
  • Laboratory Type/Application*
  • Samples/Week*
  • Name*
  • Company*
  • Department
  • Email*
  • Phone*
  • Fax
  • Other
  • Submit Message Reset Message